Files
hamlab/SENSORS.md
T
Mitchell-JohnsonandClaude Fable 5.1 b05a053920 Sensors: read-only tokens, live stream, Prometheus, status sensors, widgets, embeds
- sensors:read tokens open the sensor endpoints (here and on managed machines
  through the hub) and nothing else; full tokens are never accepted from a URL
- /api/sensors/stream: a shaped query that keeps answering, over SSE
- /metrics: Prometheus text format
- services, updates, ZFS and SMART as background status sensors
- widget library over the sensor API; custom widgets on the dashboard
- /embed/widget: one live widget in its own bundle, the only frameable path
- Dashboard tab is now Monitors

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
2026-09-19 07:37:10 -07:00

179 lines
7.5 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Sensors — the standard read interface
Everything Ham Lab measures is a **sensor**: a stable dotted ID, a little metadata, a
current value. Any consumer — Ham Lab's own dashboard, Glance, Home Assistant, a shell
script — discovers them from the catalog and asks for exactly the ones it wants.
Code: `internal/sensors` (types, registry, selectors, shaped query) and
`internal/metrics/sensors.go` (the collector as a provider). The registry measures
nothing; providers do. A new source of sensors implements `sensors.Provider` and is
added to the registry in `api.New`.
## IDs
```
cpu.usage cpu.core.<n>.usage cpu.temp load.1|5|15 uptime
mem.total|used|avail|free|cached|buffers|used_pct swap.total|used|avail|used_pct
temp.<chip>.<label> fan.<chip>.<label>
net.<iface>.rx|tx|rx_total|tx_total|up
disk.<dev>.read|write|util|size|temp
fs.<mount>.size|used|used_pct
ups.battery|runtime|load|load_pct|in_v|out_v|on_battery|state|source
```
- Segments are lower case `[a-z0-9_-]`: `Package id 0` → `package_id_0`, `/mnt/tank` →
`mnt_tank`, `/` → `root`. The real names are in the sensor's `labels`.
- Built from names the hardware reports, never enumeration order (`hwmon3` moves between
boots). Two identical chips collide; the second gets `_2`.
- Which sensors exist differs per machine. That is the point of the catalog.
## A sensor
```json
{ "id": "temp.coretemp.package_id_0", "name": "coretemp Package id 0",
"kind": "temperature", "unit": "°C", "value": 51, "t": 1789826600878,
"warn": 105, "crit": 105, "labels": { "chip": "coretemp", "label": "Package id 0" } }
```
`value` is a number, bool or string. `t` is when it was really read, in unix ms — slow
sections (filesystems 30 s, UPS 10 s) are older than the tick. `min`/`max` are the scale
(0–100 for percentages, 0–total for used bytes); `warn`/`crit` are the hardware's own
thresholds where it states them.
## Endpoints
All behind the same auth as the rest of `/api` (session cookie or `Authorization: Bearer`).
On a hub, every one is also at `/api/nodes/<machine>/sensors…` for each managed machine.
| | |
|---|---|
| `GET /api/sensors` | Catalog, with current values. `?ids=fan.*,cpu.usage` narrows it. |
| `GET /api/sensors/{id}` | One sensor. `?format=text` → the bare value as text/plain. |
| `GET /api/sensors/{id}/history` | `{id, unit, t[], v[]}` — what the ring holds (300 samples at the sampling interval). Numbers only. |
| `POST /api/sensors/query` | Shaped query, below. |
| `GET /api/sensors/query?k=selector&…` | The same, flat, for consumers that can only fetch a URL. |
A selector is an exact ID or a glob. `*` crosses dots: `fan.*` is every fan,
`cpu.core.*.usage` every core.
## Shaped query
Send the object you want, with selectors where the values go. Get it back filled in.
```
POST /api/sensors/query
{ "cpu": "cpu.usage", "fans": "fan.*", "box": { "temp": "cpu.temp", "up": "uptime" } }
→ { "cpu": 12.4,
"fans": { "fan.nct6775.fan1": 820, "fan.nct6775.fan2": 1140 },
"box": { "temp": 41, "up": 80520 } }
```
- Exact ID → its value; `null` if this machine has no such sensor (so one query works
across machines that differ).
- Glob → an object keyed by ID; `{}` if nothing matches.
- Objects and arrays are walked; anything else in a query is a 400.
- `?full=1` → every value is the whole sensor object instead of the bare value. (In the
GET form `full` is therefore not usable as a key.)
## Live stream
`GET /api/sensors/stream` is a shaped query that keeps answering: the same object, pushed
as a server-sent event after every sample. The query is `?q=<URL-encoded JSON shape>` or
the flat form; `?full=1` as above; `?every=<ms>` spaces events out for a consumer that
doesn't want them at the sampling rate. A keepalive comment goes out every 25 s, and
`X-Accel-Buffering: no` keeps nginx from holding events back.
```js
new EventSource('/api/sensors/stream?token=…&q=' + encodeURIComponent(JSON.stringify({ cpu: 'cpu.usage', fans: 'fan.*' })))
.onmessage = (e) => render(JSON.parse(e.data))
```
## Auth: read-only tokens
Settings → Access tokens → **+ Read-only sensor token** (or `POST /api/tokens/read
{"name"}` with a session). Scope `sensors:read`: it opens every endpoint in this file,
here and on each managed machine through the hub (`/api/nodes/<machine>/sensors…`; the
hub talks to the node as itself, the caller's token stops at the hub), and nothing else.
- Send it as `Authorization: Bearer <token>`, or as `?token=<token>` where headers are
impossible (an iframe, a browser `EventSource`).
- A **full-control token is never accepted from a URL**, and a read-only token is never
accepted anywhere outside this file's endpoints.
## Prometheus
`GET /metrics` (or `/api/sensors/prometheus`, which also works through the hub as
`/api/nodes/<machine>/sensors/prometheus`). One gauge family per kind of measurement,
base units, the sensor ID and its real-world names as labels:
```
hamlab_temperature_celsius{id="temp.coretemp.core_0",chip="coretemp",label="Core 0"} 50
hamlab_usage_percent{id="fs.root.used_pct",fstype="ext4",mount="/"} 10.1
hamlab_state{id="ups.state",model="CPS CP1500PFCRM2U",value="Normal"} 1
hamlab_updates_pending{id="updates.pending",manager="apt"} 3
```
```yaml
scrape_configs:
- job_name: hamlab
authorization: { credentials: <read-only token> }
static_configs: [{ targets: ['10.0.0.234:8100'] }]
```
## Status sensors
Not everything is a /proc number. These are read in the background on their own clocks
(each sensor's `t` is its real age) by `internal/api/status_sensors.go`:
```
services.failed|failed_names|running every 30 s
updates.pending|security|reboot_required every 5 min
zfs.<pool>.health|healthy|size|used|used_pct|frag every 1 min
smart.<dev>.passed|warnings|power_on|wear every 10 min, never waking a sleeping disk
```
## Widgets
A widget is a spec — `{type, sensor, title?}` — over this API and nothing else
(`web/src/widgets.tsx`, fed by `useSensorStream` in `web/src/sensors.ts`). Types: `stat`,
`gauge`, `bar`, `spark`, and `list` for a pattern. Scale and colour come from the
sensor's own `min`/`max`/`warn`/`crit`.
- **In Ham Lab:** Monitors → Customize → **+ Add widget**. Saved with the layout,
per machine; all of a page's widgets share one stream.
- **Anywhere else:** `/embed/widget` is one widget alone on a page, live, in its own small
bundle (the console never loads), and the only path Ham Lab allows to be framed.
```
/embed/widget?type=gauge&sensor=cpu.usage&token=<read-only token>
&machine=grid &title=… &theme=dark|light|cyberpunk|retro &every=<ms> &bare=1
```
### Glance
Glance's own `custom-api` widget refetches on page load / cache expiry — fine for slow
facts, never live. An `iframe` of the embed is live.
```yaml
- type: iframe
title: core CPU
source: https://hamlab.bigham.dev/embed/widget?type=gauge&sensor=cpu.usage&bare=1&token=<read-only token>
height: 130
- type: custom-api
title: grid
cache: 1m
url: https://hamlab.bigham.dev/api/nodes/grid/sensors/query?pool=zfs.tank.used_pct&failed=services.failed&updates=updates.pending
headers: { Authorization: Bearer <read-only token> }
template: |
<div>tank {{ .JSON.Float "pool" }}% · {{ .JSON.Int "failed" }} failed · {{ .JSON.Int "updates" }} updates</div>
```
## Not yet
- The stock Monitors modules (CPU, Temperatures, Network…) still read `/api/metrics`;
only custom widgets run on sensors. Porting them is the remaining dogfooding.
- Per-unit service sensors, containers, token restriction to ID patterns, a fleet-wide
query in one request.