Top: a hyper-thread wears its core's temperature, and the columns line up
The process table carries each logical CPU's core id from sysfs topology; a row with no reading still has the temperature cells, so the % column is one column. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Fable 5.1
parent
41e63f74e9
commit
4280b2226a
@@ -1011,6 +1011,34 @@ func uidName(uid string) string {
|
||||
return n
|
||||
}
|
||||
|
||||
// coreIDs maps logical CPUs to physical cores from sysfs topology: on a chip with
|
||||
// hyper-threading, CPUs 8–15 are the second threads of cores 0–7, and coretemp names its
|
||||
// sensors by core. Read once; the topology does not change while we run.
|
||||
var (
|
||||
coreIDsOnce sync.Once
|
||||
coreIDsVal []int
|
||||
)
|
||||
|
||||
func coreIDs(n int) []int {
|
||||
coreIDsOnce.Do(func() {
|
||||
for i := 0; ; i++ {
|
||||
b, err := os.ReadFile("/sys/devices/system/cpu/cpu" + strconv.Itoa(i) + "/topology/core_id")
|
||||
if err != nil {
|
||||
break
|
||||
}
|
||||
id, err := strconv.Atoi(strings.TrimSpace(string(b)))
|
||||
if err != nil {
|
||||
break
|
||||
}
|
||||
coreIDsVal = append(coreIDsVal, id)
|
||||
}
|
||||
})
|
||||
if len(coreIDsVal) < n {
|
||||
return nil
|
||||
}
|
||||
return coreIDsVal[:n]
|
||||
}
|
||||
|
||||
// ProcTable is the Processes tab payload.
|
||||
type ProcTable struct {
|
||||
T int64 `json:"t"`
|
||||
@@ -1021,6 +1049,7 @@ type ProcTable struct {
|
||||
CPUMHz float64 `json:"cpu_mhz,omitempty"`
|
||||
CPUMaxMHz float64 `json:"cpu_max_mhz,omitempty"`
|
||||
CPUTemp float64 `json:"cpu_temp,omitempty"`
|
||||
CoreIDs []int `json:"core_ids,omitempty"` // for each logical CPU, the physical core it is a thread of (what the temperature sensors are named by)
|
||||
Load [3]float64 `json:"load"`
|
||||
Mem Mem `json:"mem"`
|
||||
Swap Mem `json:"swap"`
|
||||
@@ -1204,6 +1233,7 @@ func (c *Collector) Processes() ProcTable {
|
||||
if n := len(c.ring); n > 0 {
|
||||
last := c.ring[n-1]
|
||||
t.CPU, t.Cores, t.Net, t.CPUTemp = last.CPU, last.Cores, last.Net, cpuTemp(last.Temps)
|
||||
t.CoreIDs = coreIDs(len(last.Cores))
|
||||
from := n - 90
|
||||
if from < 0 {
|
||||
from = 0
|
||||
|
||||
Reference in New Issue